[China Glass Net] In the process of home decoration construction, we will feel the gap between the glass door and window after the installation and construction of the door and window. When installing the glass, the size of the pad or glass blank is not as large as required, and the pad cannot be placed. The block makes the glass directly contact with the glass groove, the peripheral space is uneven, the weight of the glass cannot be well supported, and the sash is deformed in severe cases. What should I do if there are cracks in the glass doors and windows during the home decoration? Glass door and window gaps are analyzed and solutions are presented.

There are gaps in the glass doors and windows that cause this situation:

1. When the glass is installed, the debris in the notch is not removed in time, so that the glass and the notch are not aligned.

2. The gap between the glass and the glass slot is uneven. The rubber strip is in poor contact with the glass and the glass slot. The glass slot is protruded, and the sealing strip can be easily pulled off by hand.

3. The rubber strip is not broken at the corner, and it is not glued.

Glass doors and windows have gap prevention measures:

1. Install the glass block according to the regulations to support the weight of the glass to avoid deformation of the window sash. The glass installed in the vertical frame should be provided with two load-bearing blocks underneath, and the distance between the resting points and the vertical edge of the glass is l/4 and not less than 150 mm of the glass width. In other directions, the block should be set to fix the glass to ensure uniform gaps around.

2, the glass block should use a hard rubber with a hardness of 80 degrees, the width should be greater than the thickness of the supported glass, the length is not less than 25mm, the thickness is generally 2 ~ 6mm.

3. Before the glass is in place, check the position of the block to prevent the block from falling off due to collision and vibration. The position is not allowed and the drain hole is blocked.

4. Strictly control the size of the glass cut. The difference between the size of the glass and the size of the frame fan should be equal to the thickness of the two blocks.

Measures for rectification of glass door and window gaps:

1. Before installing the glass, carefully remove the debris in the slot, such as mortar, brick scraps, wooden blocks, etc. When the glass is placed, it should be carefully centered to ensure uniform gap on both sides, and fixed in time to prevent collision displacement and deviation. The center of the slot.

2, the rubber sealing strip can not be pulled too tight, the length of the blanking is 2o-3omm longer than the assembly length. It should be set in place during installation, the surface is straight, and it is in close contact with the glass and glass slot, so that the surrounding force of the glass is evenly distributed. At the corner, the rubber strip should be beveled off and glued firmly at the break.

3. When sealing the glass with sealant, the glass should be squeezed with rubber strips or rubber blocks to leave a gap of glue injection. The depth of glue injection should be no less than 5mm. Before the glue is cured, the glass should be kept from vibration.

Cold Dyeing Fabric

One of normal fabric, can be made to blouse,shirts etc.its color fastness is better than regular dyeing.Also Shrinkage and Torque is better than regular dyeing.it can save much water and energy.One of normal fabric, can be made to blouse,shirts etc.its color fastness is better than regular dyeing.Also Shrinkage and Torque is better than regular dyeing.it can save much water and energy.One of normal fabric, can be made to blouse,shirts etc.its color fastness is better than regular dyeing.Also Shrinkage and Torque is better than regular dyeing.it can save much water and energy.